Victoria Arduino E1 Prima
| Maker | Victoria Arduino |
|---|---|
| Boiler | Instant-heating brew (NEO) plus steam boiler |
| Brew boiler | Not listed |
| Steam boiler | 1.5 L |
| Water tank | Not listed |
| Plumb-in | Yes |
| Voltage (US) | 110-120V version |
| Maker's water filter | Not listed |
What water does this machine require?
Victoria Arduino hasn't published a limit our check can use for this machine yet, so the check can't give it a result. Whatever the maker does say is quoted below.
Shown, but not used to decide (5)
- Total hardness, 50–60 ppm. Written for another model or range. We're verifying whether it applies to this machine; until then it doesn't decide. The maker's words for Total hardness.
- Total dissolved solids (TDS), 50–250 ppm. Written for another model or range. We're verifying whether it applies to this machine; until then it doesn't decide. The maker's words for Total dissolved solids (TDS).
- Total alkalinity, 10–150 ppm. Written for another model or range. We're verifying whether it applies to this machine; until then it doesn't decide. The maker's words for Total alkalinity.
- Total chlorine, below 0.5 mg/l. Our reading of the maker's words is being checked again; until then it doesn't decide. The maker's words for Total chlorine.
- pH, pH 6–8. Written for another model or range. We're verifying whether it applies to this machine; until then it doesn't decide. The maker's words for pH.
Will my water work with this machine?
Add your water from a test strip, a report or your city's numbers, and we'll check it against the maker's limits above. It stays in this browser.
The maker's water guidance
From Victoria Arduino's guidance for Eagle One Prima user handbook (2021).
Total hardness: 50–60 ppm
“WATER SPECIFICATIONS ... Total hardness 50-60 ppm (parts per million).”
Total dissolved solids (TDS): 50–250 ppm
“WATER SPECIFICATIONS ... tds (total dissolved solids) level between 50 – 250 ppm.”
Total alkalinity: 10–150 ppm
“WATER SPECIFICATIONS ... Alkalinity level between 10 - 150 ppm.”
Total chlorine: up to 0.5 mg/l
“WATER SPECIFICATIONS ... Chlorine level less than 0.50 mg/l.”
pH: 6–8
“WATER SPECIFICATIONS ... ph level between 6.0 - 8.0.”
Warranty
“Failing to maintain water into the correct levels will void the warranty.”
Hardness, highest
“Plumbing requirements. Prepare a suitable drain and a mains that supply water a maximum hardness of 3/5 French degrees (60/85 ppm).”
Water filter
“Filtration level below 1.0 micron.”
Where to buy
No store link yet